Description
Practically, two kinds of methods are widely used for cable faults pre-location. One is pulse reflection, another is MURRAY Electric Bridge.
Compared with pulse reflection, Electric Bridge is easy to use for operation, especial for fault analysis.
However, Electric Bridge must be have its disadvantage. One example, for primary insulation layer of high resistive cable faults, it is difficult to test. In addition, its precondition is the tested cable length is available and accurate.
Applications
In theory, Electric Bridge for cable test can divided into three types, DC resistor bridge for low resistive cable faults with resistance <10kohm. DC high voltage bridge for high resistive cable faults with resistance between 10kohm and 10M ohm. The third one is AC Schering bridge for Dissipation factor test.
Model CSF 601 is one DC high voltage bridge, its typical application as below.
² Medium & low voltage cable ground faults, single, two, even three phase.
² High voltage cable sheath fault, especial for those 66KV single-core power cable.
Besides typical main applications above, Model CSF 601 two secondary applications as below.
² As DC High Voltage withstand supply, with output up to 15KVdc, the max.current 30mA
² Burning down fault point to reduce high resistance.
As for its application field, Model CSF 601 can be used at jobsite or cable manufacturer.
Fig.1 Outline Photo of CSF601
Fig.2 Electric bridge principle
Fig.3 Connection diagram for Fault location of multi-cores cable
Fig.4 Connection diagram for Cable Sheath Fault location
Product Features
² Same test principle to international famous brand, however Higher output voltage
² Separated designed for HV & LV section, operating the bridge by insulating rod, ensure safety;
² High accuracy by rising the bridge sensitivity and eliminate lead resistance error
² Wide applications
² Powered by rechargeable battery or power supply
² Lightweight ,small size
Specifications
² DC Output: 0~15KV
² Short-circuit current: 30mA
² Location accuracy of proportion: ±(0.2%L+1)m
² Power supply: 220V±10%,50Hz or 9V battery
² Volume: 380mm×360mm×270mm
² Weight: 10kg
Order Information
Item Art. No.
Model CSF601 Packing list as below
No. | Description | Qty. | Remark |
1 | HV cable sheath fault locator | 1 piece | Main Instrument |
2 | Discharging rod | 1 piece | |
3 | Grounding line | 1 piece | |
4 | Lower resistance short-circuit wire | 1 piece | suitable for cable below 35KV |
5 | 9V battery | 1piece | |
6 | fuses for spare | 2 pcs | 5A, 5×20 |
Cable Sheath Fault Pinpointer, Model CSP 701, is optional for high accuracy fault location.
For low voltage Cable Sheath Fault or more cable fault location, pulse reflection is recommended.
Model CSF601 Cable Sheath Fault Locator